Measuring instruments (analog)
ER 196
|
Voltmeter (90°)
|
Model No.
|
- Operating frequency 40÷60 Hz - CLASS 1,5
- Ranges:
- 50/60 Hz 600V direct input
|
ER 172
ER 196
|
ER196
ER196 Ammeter with switch
|
Ammeter (90°)
|
Model No.
|
- Operating frequency 50/60 Hz
- Class 1,5
- Ranges:
- Ammeters: 1-1,5-2,5-4-5-6-10-15-20-25-30-40-50-60A direct input
- .../1A, .../5A input by means of C.T. with secondary 1A or 5A
|
ER 172
ER 196
|
4RK46
|
Hour Meter
|
Model No.
|
The hour meters are instruments for measuring time which are particularly
suitable for:
- Determining the functioning time of electrical machines, elevators, boilers,
electrical stoves etc.
- Determining the intervention time for changing the oil, replacing ball
bearings etc.
- Determining the sum of the periods during fatigue tests, the duration of
electrochemical processes etc.
|
4RK 46
4RH 72
|
ERW96/1
Wattmeters and Varmeters for for alternating current
with incorporated electronics
|
Model No.
|
|
|
ERW96
|
ERF96
|
Frequency Meter
|
Model No.
|
|
- Switchboard version (90°)
- Switchboard version (240°)
- Class 0,5
- Ranges 45/65Hz 110V, 230V or 400V
- Thermic drift 0,12% / °C
|
90°
ERF 48
ERF 72
ERF 96
ERF 144
|
240°
ERFL 72
ERFL 96
|
2ERID72A230
Ammeters (Digital)
- Power supply: 230VAC ±10% standard 50/60Hz.
- Frequency: 45/65 Hz
- Display: 1 display 4 digits red colour. Digit height 14 mm (8 mm for model 48x48)
- End scale value from 1 to 9000A with 5A steps, selectable by a frontal button
- AC range input 5A - it is necessary to connect the CT .../5A correspondent to the end scale value
set DC Range Input 60mV - it is necessary to connect the shunt.../60mV 2ERID36A230, 2ERID48A230, 2ERID488A230, 2ERID72A230, 2ERID96A230
2ERID72V230
Voltmeters(Digital)
- Burden / power supply: 1VA / 230VAC ±10% standard 50/60Hz.
- Frequency: 45/65 Hz
- Class 0,5% ±2 digit referred to the end scale
- Display: 1 display 4 digits red colour
- Digit height 14 mm (8 mm for model 48x48)
- AC range 500V standard. 100V and 110V VT insertion on request
- DC range 500V standard
2ERID36V230, 2ERID48V230, 2ERID488V230, 2ERID72V230, 2ERID96V230
TARPDE1, 25A CT 25/5A
TAR3D250A CT 250/5A
Standard Series - Current Transformers
- The short circuit on terminals or the connection to earth can be achieved by the double fast-on or
connecting two wires on the same terminal
- Sealable terminals cover included
- Different characteristics on request
- Fixing system: to wall or to DIN rail by accessories supplied together with the current transformer
- Secondary current 1A on request
TARPDE1
Transformer with wound primary cable,primary and secondary currents on the terminals Ranges
TARPDE1 1A,TARPDE1 5A,TARPDE1 10A,TARPDE1 15A,TARPDE1 20A-40A TAR3D,TAR4D,TAR5,TAR8,TAR12
Transformer suitable for primary current by cable or busbar Ranges
50A to 4000A
1RLUX
Astronomical Time Switch Model: 1RLUX.
The device is an electronic time-switch to manage electrical appliances from sunset to dawn, according to the geographic area set. It performs type 1B actions and is designed for household and similar purposes in environments with normal pollution degree and overvoltage category III. Reference standards: Compliance with Community Directives 2006/95/CEE (Low Voltage - LVD ) and 2004/108/CE ( Electromagnetic compatibility E.M.C.) is declared with reference to the following standards :
CEI EN60730-2-7 E.M.C. : CEI EN 61000-6-1 / CEI EN 61000-6-3
|