Din Modular Protection Products
DIN Modular Protection Products
Safety and protection are the prime purposes of Terasaki products. The Terasaki range of DIN Modular Protection products covers ratings from 0.5A to 125A and includes: -Circuit breakers for overload and short-circuit protection -Residual current devices for the prevention of electric shock and fires -Circuit breakers combining overload,short-circuit and residual current protection With more than 500 items in the range, there is a solution for most applications.
TD3MO6 1P, 10A, 6kA
Designation Poles Din
Modules
B Type C Type D Type
Miniature Circuit Breakers
TD3 M06 6kA MCBs
         
Certified by KEMA Breaking
capacity: Icn = 6kA to EN 60898.
Voltage: Un: 230 -240V AC
phase-to-neutral,400-415V AC
phase-to-phase
1P
1P+N
2P
3P
3P+N
4P
1
2
2
3
4
4
6-63A

6-63A
6-63A

6-63A
6-63A
6-63A
6-63A
6-63A
6-63A
6-63A
 
TD3M10 3P, 16A, 10kA
Designation Poles Din
Modules
B Type C Type D Type
TD3 M10 10kA MCBs          
Certified by KEMA
Breaking capacity:
Icn = 10kA to EN60898,
leu = 15kA to EN 60947-2
Voltage: Un: 230 -240V AC
phase-to-neutral, 400-415V
AC phase-to-phase
1P
1P+N
2P
3P
3P+N
4P

2
2
3
4
4
16 -63A

6-63A
6-63A

6-63A
2-63A
6-63A
2-63A
2-63A
2-63A
2-63A
1 -63A

1 -63A
1 -63A

1 -63A
Designation Poles Din
Modules
B Type C Type D Type
TD3 XA MCBs          
Breaking capacity:
Icn = 10kA to EN 60898
Breakinq capacity:
leu = 10kA to EN 60947-2
1P
2P
3P
4P
1.5
3
4.5
6
80-125A
80-125A
80-125A
80-125A
80-125A
80-125A
80-125A
80-125A
 
TD3RCCB 40A,4P,100mA
Designation Poles Din
Modules
30mA 100mA 300mA
Residual Current Circuit          
Breakers
TD3RCCB
Residual current circuit
breaker with overload
protection
TD3RCBO
2P
2P
2
4

1
2
25 - 63A
25-100A

6-40A
25-100A
25 - 63A
25 - 63A
25 - 63A
25 - 100A

 
25-100A
TD3RCCB 25A,2P,100mA
Designation Poles   Ratings    
Modular Switches TD3 MS          
Standard: EN 60947-3 1P
2P
3P
4P
  32,63,125A
63.125A
63.10.125A
63,100,125A
   
TD3MS 3P, 63A

Accessories for TD3 M06, TD3 M10, TD3 XA, TD3RCCB
-Auxiliary contact, 1NO, 1NC. 6A, 230V AC . Not suitable for TD3RCCB
-Alarm contact, 1NO, 1NC. 6A, 230V AC . Not suitable for TD3RCCB
-RCCB switch. Combined auxiliary contact (1NO, 1NC. 6A, 230V AC) + Alarm contact (1NO, 1NC.
6A, 230V AC)
-Shunt trip. RCCB switch (C) must be fitted before fitting the shunt trip to the TD3RCCB
-Under voltage trip. RCCB switch (C) must be fitted before fitting the under voltage trip to the TD3RCCB
-Over voltage trip. Rated voltage, Un, 230V AC. Opens the circuit breaker if supply voltage exceeds 280V AC. RCCB switch (C) must be fitted before fitting the over voltage trip to the TD3RCCB
Residual Current Block for TD3 M06, TD3 M10

    In = 63A maximum  
Din
Modules
30mA 300mA 1000mA
2
4
2 Types AC, A
4 Types AC, A
Types AC, A
Types AC, A

Types AC A, S

Handle for TD3 ICP Rotary handle clips onto TD3 ICP miniature circuit breakers, and operates the device from outside the door.